Figure
|
Description
| Page No.
|
1
|
Correlation between mechanical and magnetic properties
| 14
|
2
|
Hysteresis for magnétic hard (Martensitic) and soft (Ferrite) materials
| 15
|
3
|
Methodologies applied for material characterization
| 15
|
4
|
The EC principle
| 16
|
5
|
Magnétic hysteresis loop and operating points
| 17
|
6
|
EC impedance plane
| 18
|
7
|
Ferromagnetic hysteresis (top) and incremental permeability μA (bottom)
| 18
|
8
|
Incremental permeability
| 18
|
9
|
Harmonic distortion
| 19
|
10
|
Visualization of harmonic distortion
| 19
|
11
|
Structure of the trolley (view 1)
|
20
|
12
|
Structure of the trolley (view 2) |
21
|
13
|
Sensor system in aluminum housing |
22
|
14
|
Two views of the Inspection unit |
23
|
15
|
Exchanging the probes
|
23
|
16
|
Exchanging the rollers
|
24
|
17
|
Exchanging the pressure spring and rubber buffer |
24
|
18
|
Battery housing |
25
|
19
|
Wiring scheme battery housing |
26
|
20
|
ODU-MAC connector pin assignment |
26
|
21
|
Elements on Mains Power Supply Unit
|
26
|
22
|
Wiring diagram mains power supply unit
|
27
|
23
|
Position of encoder (bottom view)
|
27
|
24
|
Battery storage station
|
28
|
25
|
Elements on the electronics front panel
|
29
|
26
|
Connections on the electronics back panel
|
29
|
27
|
Chalk marking unit
|
30
|
28
|
Swiveling the guide rollers
|
31
|
29
|
Exchanging the guide rollers
|
31
|
30
|
Removing the socket and the shaft (1)
|
32
|
31
|
Removing the socket and the shaft (2)
|
33
|
32
|
Removing the rail rollers
|
33
|
33
|
Removing the vertical rail system
|
34
|
34
|
Removing the horizontal rail system
|
35
|
35
|
Exchanging snapping and clamping piece
|
36
|
36
|
Login
|
37
|
37
|
Running and stopping the measurement
|
38
|
38
|
Overview of Inspection tab (1)
|
39
|
39
|
Overview of Inspection tab (2)
|
40
|
40
|
Influence of Frame button on measurement progress
|
41
|
41
|
Measurement report
|
44
|
42
|
Overview of Measurement and calibration tab
|
45
|
43
|
Normalization sub-tab
|
46
|
44
|
Calibration sub-tab |
46
|
45
|
Harmonics & raw signals sub-tab
|
48
|
46
|
Incremental permeability sub-tab
|
48
|
47
|
Eddy current sub-tab
|
49
|
48
|
Settings sub-tab |
49
|
49
|
Channel tuning sub-tab |
49
|
50
|
Raw signals tab |
51
|
51
|
Expert settings tab
|
52
|
52
|
Device settings |
52
|
53
|
Calibration settings
|
53
|
54
|
Changed parameters after calibration
|
54
|
55
|
Compensations settings
|
54
|
56
|
Other settings |
55
|
57
|
overview of machine learning procedure |
56
|
58
|
Normalization procedure (1) |
57
|
59
|
Normalization procedure (2)
|
57
|
60
|
Normalization database filled
|
58
|
61
|
8-channel calibration of OK/NOK area |
58
|
62
|
Calibration procedure after normalization |
58
|
63
|
Overview of inspection procedure |
68
|
64
|
Short run
|
69
|
65
|
Long run
|
70
|
66
|
Iteration 1 – Measurement |
71
|
67
|
Iteration 2 – Find limits |
71
|
68
|
Iteration 3 – Turn short run |
72
|
69
|
Iteration 3 – Combine stripes
|
73
|
70
|
Temperature compensation module in the MMS software
|
74
|
71
|
GUI Temperature compensation
|
74
|
72
|
Performing measurement after compensation
|
78
|
73
|
Expert settings tab, Server IP port for bar code reader
|
79
|
74
|
Inspection tab with bar code reader indicator at specimen number |
80
|