Structure and handling of the trolley


3.8 Lifting handle

Move the lifting handle (see pos.  10  in Figure 11) forwards to place the inspection unit on the plate.
Move the lifting handle backwards to lift the inspection unit from the plate.

3.9 Gas brake

When applying the lifting handle (see pos. 
10  in Figure 11) for testing, the gas brake allows a soft touchdown of the inspection unit onto the steel plate.

3.10 Transversal adjustment

Swivel the handle (see pos. 
in Figure 11) to the right or left to move the inspection unit by 80 mm to the corresponding transversal direction. This mechanism helps to minimize the blind zone at the longitudinal plate edges.

3.11 Crane eyes

The trolley is equipped with three eyelets. They shall be used for any lifting operations which may be required for transportation purposes.