Structure and handling of the trolley
|
3.5 Electronic unit
The measurement electronics of the mobile hard spot detector consists of an eight-channel
power amplifier and a measurement unit. A tablet PC with the 3MA-X MMS measurement
software in connected via USB to the electronic unit.
The input voltage range for battery operation mode is 23 V to 30 V. The system shuts down at
a voltage below 21,5 V and above 32,7 V.
The following elements are located on the front:
Figure 25: Elements on the electronics front panel
Table 6: Elements on front panel
Label
|
Description
|
PK1, ... , PK8
|
Battery housing
|
Temp
|
Adjustable foot
|
End
|
Fixing plate
|
Koordinaten
|
Roller track
|
The following elements are located on the back panel: The fuse type is a „T 30A, 6x32 mm“ (Schurter 8020.0607.G).
Figure 26: Connections on the electronics back panel
Table 7: Elements on back panel
Label
|
Description
|
22-32V DC
|
ODU Power connector
|
ON
|
Indicator LED
|
30A
|
Input fuse
|
USB
|
Connector to tablet PC
|
I/O
|
Power Switch
|