Operating and Maintenance Instructions
adaptaed from: https://app.box.com/s/c6qfgtuhfg1yd2ottrfum98x8jmg7rn3
Hard spot inspection trolley • PLAMAT-M •
18201 |
|
Operating and
Maintenance Instructions • V2.0 |
Structure and handling of the trolley
|
3.1.2 Exchanging the rollers
Exchange
the wheel when observing improper balance and excessive wear. To do so,
conduct the following steps as illustrated in the figure below:
- Untighten the screws and remove the plate.
- Pull out the axle.
- Remove the wheel with the two composite bushings.
- Apply (press) two new bushings to the new wheel.
- Insert the new wheel.
- Push in the axle, note that the rabbet fits into proper position of the plate.
Figure
16: Exchanging the rollers
3.1.3 Exchanging the tension spring and rubber buffer
Please proceed analogously to section 3.1.2.
Figure 17: Exchanging the pressure spring and rubber buffer
3.1.4 Cleaning of the probes and steel plate
Probes: The bottom of the probe heads can be covered with dust (impedes movement of
trolley). Clean them regularly with a brush.
Steel plate: Sweep the steel plate from raw dirt, especially ferromagnetic components.
ROSEN and IZfP Page 24 of
84 |
Confidential! |
|